Use and maintenance of centrifuge

Time: 2020-03-31

1. Before running the centrifuge, please cut off the power and release the brake of the centrifuge. You can try to rotate the drum by hand to see if there is any bite brake.

2. Check for looseness and abnormality in other parts.

3. Turn on the power and drive in clockwise direction (usually it takes about 40-60 seconds from the standstill to normal operation). Normally, each device must be run empty for about 3 hours after arriving at the factory, and it can work without abnormal conditions.

4. The material should be placed as evenly as possible, and must be operated by a person, and the capacity must not exceed the rated amount.

5. It is strictly forbidden to run the machine at overspeed to avoid affecting the service life of the machine.

6. After the machine is started, if there is any abnormal situation, it must be stopped and inspected. If necessary, it must be disassembled, washed and repaired.

7. The centrifuge is running at high speed, so do not touch the drum with your body to prevent accidents.

8. The mesh size of the filter cloth should be determined according to the size of the solid phase particles of the separated material, otherwise it will affect the separation effect. In addition, the filter cloth should be installed when the filter cloth is installed.

9. The sealing ring is embedded in the drum sealing groove to prevent the material from running in.

10. To ensure the normal operation of the centrifuge, please refuel and maintain the rotating parts every 6 months. At the same time, check the running lubrication condition of the bearing for wear; whether the components in the braking device are worn, replace them seriously; and whether there is oil leakage in the bearing cover.

11. After using the machine, clean it well and keep the machine tidy.

12. Do not separate non-corrosion-resistant centrifuges from highly corrosive materials; otherwise, operate strictly in accordance with equipment requirements and regulations. Non-explosion-proof centrifuges must not be used in flammable and explosive situations.

E-MAIL

ID : 

@yongda.cn

PW : 

GK series horizontal scraper unloading automatic centrifugeGKF series clean horizontal scraper unloading automatic centrifugeGKC series wall-mounted clean aseptic scraper unloading automatic centrifugeGKH series siphon horizontal scraper unloading automatic centrifugeHR series horizontal double-stage piston pusher automatic centrifuge